Skip to main content

Technical Details

  • Variable Type: Event
  • Data Type: Integer
  • Units: Frame number
  • Column Name: sit_frame
  • Required for QA: True
  • Recurring: One frame per repetition
  • Measurement: First frame after the descent at which the pelvis is within 10% of the repetition’s descent amplitude above the low point the descent ends at

Description

Sit marks the moment the person returns to the chair at the end of a repetition. For each repetition, Uplift follows the descent down to the low point it ends at and takes the first frame within 10% of the descent amplitude above that low point. As with Seat Off, the threshold is referenced to each repetition’s own low point so touch-and-go repetitions are detected. Sit ends the Descent phase. If the capture ends before the person sits back down, the final repetition has no Sit and the capture fails QA.